- Bacharach 0010-5057 - Fyrite® fluid, 20 60% CO2 - TEquipment
Carbon Dioxide Fluid, 3 bottle carton, 20 60% Fyrite-absorbing fluid is selective in the chemical absorption of carbon dioxide or oxygen, respectively Therefore, the Fyrite®'s accuracy, which is well within the range required for industrial and professional applications, does not depend upon complicated sequential test procedures
- FYRITE® Gas Analyzer CO2 and O2 Indicators - Bacharach
FYRITE® Gas Analyzer CO 2 and O 2 Indicators Operation and Maintenance Manual P N: 0011-9026 Revision 13 October 2015 Product Leadership • Training • Service • Reliability
- Fyrite Classic Gas Analyzer | MSA Safety | United States
The Fyrite® Classic contains fluid that is specifically designed to absorb O2 or CO2 with minimal cross-sensitivities to other gases, which leads to accurate readings It is easy to test the fluid’s strength and replace it when needed – which means no need to return the unit for service and no downtime
- How does a Fyrite work - Lab Equipment Notebook
Fluid: The fyrite fluid is mostly water For the CO2 fyrite, the “active ingredient” is potassium hydroxide (KOH) The CO2 solution is colored red for identification (The O2 solution is blue) The O2 solution has a bunch of ingredients and I have’t bothered to figure out how it works since I rarely use it (but maybe I will later)
- Fyrite™ CO2 Gas Analyzers - Thermo Fisher Scientific
Fast, accurate and easy-to-use instrument for measuring and analyzing carbon dioxide The number of tests possible with one fluid charge depends on the concentration of samples being tested; at midpoint scale reading the CO2 fluid is good for approximately 300 gas samples and the O2 fluid for 100 tests
- Fyrite Classic, Measures CO2, 0 to 20% - TEquipment
The Fyrite Classic contains fluid that is specifically designed to absorb O2 or CO2 with minimal cross-sensitivities to other gases, which leads to accurate readings It is easy to test the fluid’s strength and replace it when needed - which means no need to return the unit for service and no downtime
- Fyrite - Bacharach
Duplex Kits - Special Fyrite Kits containing various combinations of Oxygen and Carbon Dioxide Indicators, Sampling Assembly and a carrying case Repair Kits - One bottle of Fyrite fluid, valve plunger gasket, top gasket, screws, diaphragm, and envelope of filtering material Refill Kits - Two bottles of Fyrite fluid, top gasket, screws, and
- Fluid, Fyrite, CO2, 7% - Bacharach
Fluid, Fyrite, CO2, 7% Safety Data Sheet Bacharach SDS reference number 0099-1006 In accordance with Hazard Classification and Communication System of Hazardous Substances B E 2555 (2012) - Thailand Revision Date: 09 18 2017 Version: 1 1 09 18 2017 1 7 SECTION 1: IDENTIFICATION Product Identifier Product Form: Mixture
|
|