- Installing grounding plates | Information by Electrical Professionals . . .
I have a job in north jersey in a section 8 housing complex We have 3 bldgs where we cannot get rods in past a foot or so Excavator on site is going to help me either lay them horizontally or dig down for the plate My question is, do I need two plates per service like when installing rods? Or
- Porcelain wire holder plate | Information by Electrical Professionals . . .
Nichols 325 :: Hot Dip Galvanized Plate Or Rack Insulator 12Ga Steel Clevis :: PLATT ELECTRIC SUPPLY Hot Dip Galvanized Plate Or Rack Insulator 12Ga Steel Clevis W 2-1 4" Porcelain Insulator Base Plate Is 3 16" X 3" X 12" Steel, Cat #: 325, Mfr: Nichols
- RGS Bends | Information by Electrical Professionals for Electrical . . .
4R90 :: 4" Rigid Steel 90° Elbow :: PLATT ELECTRIC SUPPLY 4 Inch Rigid Steel 90 Degree Elbow, Cat #: 4R90
- SER for Range | Information by Electrical Professionals for Electrical . . .
Can #8 SER AL be used for an electric range on a 40 amp breaker? PLATT ELECTRIC SUPPLY (3) 8 AWG and
- PVC conduit fittings | Information by Electrical Professionals for . . .
Not sure how you can use PVC running thread as 362 6 says the PVC conduit and fittings must be listed and section 4 1 7 of UL 651, "Schedule 40, 80, Type EB and A Rigid PVC Conduit and Fittings" says rigid PVC cannot be threaded
- 240. 21 or 230. 46 --NEC 2020 | Information by Electrical Professionals . . .
Eaton B-Line 324 N :: 400A, 4P, 4 Jaw, Ring-Type Meter Socket :: PLATT ELECTRIC SUPPLY 400 Amp, 1-Phase, 4 Jaw, Ring-Type 3-Wire, 600V, Surface Mount, Overhead Underground Feed Manual Circuit Closing Bypass, NEMA 3R HxWxD: 32" x 14" x 6" Line and Load lug wire (1) 4awg to 600mcm or (2) 1 0awg to 250mcm, Cat #: 324 N, Mfr: Eaton B-Line
- Favorite residential 200 amp main panel and why
Eaton BR; it's what my supplier (Platt Electric Supply) carries Really started to love them when they condensed the AFCI and Dual Function breakers from the long frame to the regular frame (the CH line hang over- restricting the amount of room on the sides of the panel, as do some of the other manufacturers)
- wafer lights | Information by Electrical Professionals for Electrical . . .
That's cheap for that mounting bracket my supply house trys and sells them for $8 Lithonia Lighting WF8643-PAN-U :: New Construction Pan, 8" LED Downlight :: PLATT ELECTRIC SUPPLY New Construction Pan for 8" LED Downlight, WF8643 Pan Will Work On The 3" WF3, The 4" WF4, The 6" WF6 And The 8" WF8 LED Wafer Light Fixtures, Cat #: WF8643-PAN-U
- Is this compliant? (Chase nipples) | Information by Electrical . . .
Is this compliant? Listing issue? Bonding issue? It is a listed 90 degree rigid nipple, a rigid coupling, and a pair of chase nipples on each end Would using locknuts underneath each chase nipple (to help ensure it's bonded to the panel) change anything?
- MC in Damp location | Information by Electrical Professionals for . . .
www platt com Arlington 38AST :: MC AC Cable Connector, Snap-In, 3 8", Insulated, Zinc Die Cast :: PLATT ELECTRIC SUPPLY 3 8 inch, Snap-Tite Insulated Throat Zinc Die-Cast Connector - For AC MC Cable Range 405 to 612, Cat #: 38AST, Mfr: Arlington
|
|