- Building Connected? Your experiences, please. . .
well, i'm running the free version, and it started spewing requests to bid, so i started bidding them there is no point in getting the pro version i took the dog and pony show, and the salesman said, just bid what shows up, and see how much of it you get, and use the free version about $4k a year to get the pro version we shall see if i get anything off of it i bid 14 today, before going
- 200 amp service upgrade. | Information by Electrical Professionals for . . .
I’m looking on some insight on the best way to remove the existing interior 100amp panel and relocate all branch circuits to a new meter main combo 200amp service on the outside of the house Directly behind the old 100 amp panel All Nm-b and most are long enough to terminate in the new panel
- Fire Alarm Devices in Walk-In Cooler Freezer | Information by . . .
Does any body have any code references or requirement for fire alarm Speaker Strobes in walk in Coolers Freezers?
- 480v high leg motor issue - Mike Holts Forum
i am troubleshooting a three phase 480 motor with voltage issues that is fed by a high leg system I dont have to much experience with this set up Would the configuration of the connections to the motor matter? It is fed by a 3 wire 480v delta high leg system i did not think it would matter
- NFPA 101 SECTION 7. 8. 1. 2. 2-7. 8 ILLUMINATION OF MEANS OF EGRESS.
The jurisdictions that I work in do not adopt that section of NFPA 101, so I can't talk from an enforcement standpoint, but your conclusion seems logical BTW, although many jurisdictions adopt portions of NFPA 101, most do not adopt the whole thing For example, egress lighting in most jurisdictions are per the adopted ICC Building Code Section 1008 For another example, the 2014 Florida
- Voltage Drop: 115V equipment on 120V power
Service is 208Y 120V I am doing voltage drop calcs and it seems to me that if the equipment specs are listed for 115V, then I have an extra 5V of voltage drop to work with For example, I have a fan with the following manufacturer specs: 115V 1-Phase 11 6 FLA 1 HP From Table 430 248, the
- Bathroom Circuits | Information by Electrical Professionals for . . .
Charlie, I am under the impression that the bathroom lighting and exhaust fan is supposed to be part of the bathroom circuit At least, I was taught that the GFCI outlet should shut the lights and exhaust if it blows in a bathroom Might just be from an old code, or something, but that is my
- Leviton GFCI nuisance tripping and circuit analysis
I know many electricians and vendors, engineers encounter nuisance tripping with the Leviton GFCI After all these years Is there finally a theory why? If not Let's figure it out and analyze the circuit First This is a Waterpik mouth spray shaded-pole motor See youtube video how it works
|
|
|