companydirectorylist.com  Global Business Directory e directory aziendali
Ricerca Società , Società , Industria :


elenchi dei paesi
USA Azienda Directories
Canada Business Elenchi
Australia Directories
Francia Impresa di elenchi
Italy Azienda Elenchi
Spagna Azienda Directories
Svizzera affari Elenchi
Austria Società Elenchi
Belgio Directories
Hong Kong Azienda Elenchi
Cina Business Elenchi
Taiwan Società Elenchi
Emirati Arabi Uniti Società Elenchi


settore Cataloghi
USA Industria Directories














  • S-1 S-2 Regarding Parking Garage - The Building Code Forum
    The garage in question is not accessory to the Business occupancy and will be used to store the business Owner's large RV Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage and or carport shall be separated as required by Table R302 6 Openings in garage walls shall comply with Section R302 5 Attachment of gypsum board shall comply with Table R702 3 5 The wall separation provisions of TableR302 6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall
  • Garage Floor Drain - The Building Code Forum
    Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely flat without any slope to drain or towards door
  • fire separation in garages | The Building Code Forum
    Hello all, I have been looking into the rules for mudding and taping sheetrock in attached garages The IRC states that attached garages should be sheetrock with 1 2" on wall ceiling and 5 8" on ceiling if living space is above There is no requirement from what I can see on taping and mudding
  • 2024 Portal Frames - The Building Code Forum
    By code, one could use a portal frame to support a 20’ wide garage door, but not this case with a much smaller opening If the three windows were replaced with a triple, mulled unit, I would assume it would be acceptable, which seems somewhat ridiculous Portal frames are not just used for garage doors (except for the PFG)
  • Minimum Floor Slope for Drainage | The Building Code Forum
    The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC):
  • Commercial Repair Garages - The Building Code Forum
    One exit door of minimum width of 32", in a nonsprinklered bldg would provide egress for 160 person For the square footage provided that's 22 9375 sq ft per person Since the hazard is the vehicle with the gasoline or other fuel, I personally would use the parking garage (200 sq ft person gross) number if there were any questions




Annuari commerciali , directory aziendali
Annuari commerciali , directory aziendali copyright ©2005-2012 
disclaimer