|
- Pentair Intelliflo VSF - RPM speed | Trouble Free Pool
I have been reading a lot of the questions and answers on run time and speed for VSP I am a new pool owner, 27 5k gallons, 3HP Intelliflo VSF and a FNS Plus DE filter and SWG I currently run my pump for 12 hours at 2 8k RPM which turns my pool over 1 5times Should I run my pump at 1 4k
- How do I reset a Jandy TCX to factory default or erase its setup?
The new VSP works in standalone mode just fine Changed VSP dip switches (#3 4 both ON) Powered up and then off to change the VSP schedule mode to 'Century Connect' Connected up the RS-485 wiring for communication Powered on the Jandy TCX Now iAqualink in System Settings sees a VSP Pump I completed the setups in iAqualink for the VSP Pump
- VSP Division 3 - now encrypted? | RadioReference. com Forums
Fairfax 1 VSP have had increasing number encrypted transmisions this week by the troopers this week (upwards of 75% of the time by Wednesday) However I was still hearing the dispatchers As of today, Fairfax 1 is fully encrypted, as noted by others in this thread I have locked it out on my scanner
- Jandy Aqualink RS - Further Reading - Trouble Free Pool
The VSP motor must see a poll before it can respond Once you tell the Aqualink RS that a VSP pump is out there (via the VSP setup page), the Aqualink RS begins polling the motor’s address Century Connect can then see the polling and figure out what system it is attached to
- HP of Variable Speed Pumps Question | Trouble Free Pool
At full speed, with 40' of head, a very common starting point for many pools, a 3hp Pentair VSP can, and will try to, move 160gpm Their i2 will do 130gpm The energy wasted trying to shove so much water through those pipe sizes ends up as noise, excess filter pressure, damaged filters, channeling in sand filters, short filter cycles, un-needed
- iAquaLink with In-Floor Cleaning System | Trouble Free Pool
1 I set the VSP Speed Setup labels back to the default names (see pic 1) 2 I disabled "In-Floor" in system setup (see pic 2) 3 I cleared the schedule (see pic 3) 4 I selected "Filter Pump" from the home menu 5 The pump started priming (see pic 4) 6 After 3 minutes the pump jumped up to Preset 1 (see pic 5) IFCS Behavior: 1
- VSP Derby New Frequency 460. 375 - RadioReference. com Forums
VSP Derby is now transmitting primarily on 460 375 453 900 and 460 150 are used infrequently, possibly due to the mobile units location One Saturday night in early July the dispatcher for ST Johnsbury was handling all of the VSP communications in Orange, Caledonia, Essex and Orleans while simulcasting over all of the frequencies
- Wiring SWG Help - Trouble Free Pool
What they ended up doing was plug the SWG to a 120 V outlet and connect the VSP to the intermatic timer I suspect that they did not adjust the jumpers from the factory setting of 240 V to 120 V Also, they said that having the SWG on a plug is more convenient for taking the salt system inside to store during the winter
|
|
|